Highlights
• Electromagnetic principle - No moving parts
• High visibility backlit LCD readout
• Enables informed decisions
• Incoming water supply known
• 98% accurate
• Measures all firefighting flow rates
• Improves safety
• Can be installed on all pressurised water pipes used on fire appliance
• No ghost readings
• Not affected by debris in water
• No breakdowns as no moving mechanical parts

ALL TSI FLOW METERS FEATURE ELECTROMAGNETIC TECHNOLOGY. THE PROVEN TECHNOLOGY FOR FIRE SERVICES.

Not affected by turbulence in the water – can be installed directly onto pump manifold

No mechanical parts in water stream – not affected by any debris in the water and causes no pressure loss

Wide dynamic range – can measure the full range of fire-fighting flow rates with good accuracy

High reliability

Good accuracy. ±2% of measuring range (30 ~ 3,000 lpm)

Excellent Repeatability

‘We’ve been very pleased with the results and we have now specified TSI flow meters in all future builds as we are making the absolute best use of the water resources we have. Flow meters are a real move forward in fire-fighter safety’.
Bill Brewster, engineering manager, East Sussex Fire and Rescue Service

 

GENERAL

Model No. 33-1001
General Range: 30 – 3,000 lpm
Resolution: 50 – 750 lpm: ± 15 lpm
> 750 lpm: ±2%
Supply Voltage: DC 24V DC +20% – 10%
Negative Chassis Earth.
Supply Current: 0.35A
Operating Temp: -10 to +50ºC
Standard Functions: Flow reading, Volume used reading.

SENSOR

Measurement Principle: Electromagnetic
Casing Material: JIS ADC6, marine grade aluminium, hard anodized.
Pressure rating: 49 bar
Protection level: IP65
Inner pipe diameter: 60 mm
Dimensions: Ø140 x 210 x 100 mm
Weight: 3.0kg
Adaptor: Matched to pipework of pipe. Contact TSI.

READOUT

Digital readout of flow rate.

4-digit back-lit LCD display

Large 17.6mm digit size

Bar chart of flow reading

LPM or US GPM display.

Casing material: Polycarbonate
Protection level: IP65
Colour: Black
Dimensions: 127 x 111 x 61mm
Weight: 0.5kg